1.
Cardiovasc Pathol ; : 107647, 2024 Apr 20.
Artigo em Inglês | MEDLINE | ID: mdl-38649122

RESUMO

BACKGROUND: IgG4-related disease (IgG4-RD) is a recently recognized fibro-inflammatory disorder that can affect almost any organ. IgG4-RD has also been reported in coronary arteries as periarteritis. IgG4-related coronary periarteritis may cause coronary artery aneurysms, and IgG4-related coronary artery aneurysms (IGCAs) are life-threatening. We describe a case of a patient with IGCA that highlights the usefulness and limitations of various IGCA evaluation modalities and provides insight into disease pathophysiology. CASE SUMMARY: A 60-year-old man with IgG4-RD diagnosed 2 years before and with IGCA at the proximal right coronary artery (RCA) on coronary angiography (CAG) 9 months prior to admission to the hospital presented with acute coronary syndrome. Emergent CAG revealed the rapid progression of IGCA at the RCA, an obstruction of the diagonal branch, and stenosis of the left anterior descending artery (LAD) and the high lateral branch (HL). The patient underwent percutaneous coronary intervention for the diagonal branch. The RCA aneurysm was resected and bypassed with a saphenous vein graft (SVG); coronary bypass grafting (left internal mammary artery to LAD and SVG to HL) was performed. Pathological findings showed inflammatory cell infiltration and disruption of the elastic plate. CONCLUSION: IGCAs require careful follow-up with computed tomography scans for early detection of aneurysmal enlargement.

2.
J Vasc Surg Cases Innov Tech ; 10(3): 101447, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38510091

RESUMO

A fluoropolymer-based drug-eluting stent was implanted in an arteriovenous graft outflow venous stenosis. Two and a half years later, due to a local infection, the stent was removed surgically, and a pathological evaluation was conducted. The stent struts exhibited partial endothelial cell coverage, with the remaining surface predominantly covered by fibrin. Notably, there was no evidence of restenosis or aneurysmal change.

3.
EuroIntervention ; 20(6): e389-e398, 2024 Mar 18.
Artigo em Inglês | MEDLINE | ID: mdl-38506736

RESUMO

BACKGROUND: Drug-coated balloons (DCBs) are important treatment options for coronary artery disease; however, randomised controlled trials comparing various DCB technologies are sparse, and further investigations are needed. AIMS: This preclinical study aimed to histologically and biologically compare the drug effects and safety of a low-dose paclitaxel-coated DCB (PCB; AGENT), a regular-dose PCB (SeQuent Please NEO) and a sirolimus-coated DCB (SCB; MagicTouch). METHODS: The DCBs were inflated in the healthy iliac arteries of 18 rabbits, which were euthanised after 28 days. The treated iliac arteries and distal skeletal muscles were histopathologically evaluated, and drug concentrations were measured. RESULTS: In the histopathological evaluation, the medial smooth muscle cell loss score regarding depth, an indicator of drug efficacy, was significantly higher with AGENT and SeQuent Please NEO than with MagicTouch (4.0 [3.6-4.0] vs 3.7 [3.7-4.0] vs 2.2 [2.0-2.4]), with significant differences in comparisons between AGENT and MagicTouch (p<0.01) and between SeQuent Please NEO and MagicTouch (p<0.01). AGENT and SeQuent Please NEO showed comparable drug concentrations in the treated artery (p=0.61). In contrast, the drug concentrations in distal skeletal muscles were the highest for MagicTouch, followed by SeQuent Please NEO and AGENT (28.07 [13.19-52.46] ng/mg vs 0.66 [0.22-3.76] ng/mg vs 0.25 [0.04-3.23] ng/mg, respectively). CONCLUSIONS: This study demonstrated that PCBs might have higher efficacy and lower drug concentrations in distal skeletal muscles than the MagicTouch SCB. The efficacy of the AGENT low-dose PCB and the SeQuent Please NEO regular-dose PCB was comparable.


Assuntos
Doença da Artéria Coronariana , Bifenilos Policlorados , Animais , Coelhos , Coração , Artérias , Paclitaxel/farmacologia , Sirolimo/uso terapêutico
4.
JACC Asia ; 4(1): 1-9, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-38222261

RESUMO

Transcatheter structural heart interventions have drastically evolved over the past 2 decades. However, most catheterization procedures require the deployment of devices in the body; therefore, the adhesion of thrombi to those devices is a major problem, resulting in the requirement of a period of postprocedural antithrombotic regimen. However, in recent years, bleeding associated with these antithrombotic therapies has also become a major concern, attracting the attention of investigators. This is complicated by the fact that patients at high thrombotic risk are also at high bleeding risk, making the issue of administrating antithrombotic therapy challenging. The objective of this review was to identify the important issues and summarize the current status of postoperative antithrombotic therapy and assessment of the bleeding risk following transcatheter structural heart interventions such as transcatheter aortic valve replacement, transcatheter edge-to-edge repair, and transcatheter left atrial appendage occlusion.

6.
JACC Asia ; 3(6): 925-934, 2023 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-38155789

RESUMO

Background: There are limited data on the impact of intracardiac echocardiography (ICE)-guided transcatheter aortic valve replacement (TAVR) on the new permanent pacemaker implantation (PPMI) rate. Objectives: This study investigated the feasibility and outcome of transjugular ICE (TJ-ICE) -guided TAVR, by visualizing the relationship between the membranous septum (MS) and the transcatheter aortic valve (TAV). Methods: Among patients with severe aortic stenosis who underwent TAVR between February 2017 and June 2020, this study enrolled a total of 163 patients with TJ-ICE-guided TAVR. MS length was measured by ICE. The primary endpoint of this study was the incidence of new PPMI at 30 days. Results: The mean age of the patients in this study was 84.9 ± 4.6 years, and 71.2% of the patients were female. Device success was 96.3% with TJ-ICE guidance. A TJ-ICE-related complication occurred in 1 case (0.6%). The median length of the MS was 5.8 mm (IQR: 5.0-6.9 mm). Excellent intraobserver (intraclass correlation coefficient [ICC]: 0.94; 95% CI:0.79-0.98; P < 0.001) and interobserver (ICC: 0.93; 95% CI: -0.05 to 0.98; P < 0.001) agreements were shown. The new PPMI rate was 6.7% at 30 days without a significant difference between balloon-expandable valves and self-expandable valves (3.4% vs 8.7%; P = 0.226). Patients with a TAV implantation depth less than MS length had a significantly lower incidence of new PPMI compared with patients with a TAV implantation depth greater than MS length (2.1% vs 13.4%; P = 0.005), regardless of baseline right bundle branch block presence (6.7% vs 66.7%; P = 0.004) or absence (1.2% vs 8.2%; P = 0.041). Conclusions: TJ-ICE-guided TAVR demonstrated remarkable feasibility and safety. The TJ-ICE-guided final TAV position had a significant impact on the new PPMI rate. (Tokai Valve Registry; UMIN000036671).

7.
Cardiol Young ; 33(12): 2670-2672, 2023 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-37822181

RESUMO

Post-operative pulmonary venous stenosis is a poor prognostic factor in single-ventricle haemodynamics. Implantation of a drug-eluting stent is a therapeutic option. However, due to their small size, they inevitably become inadequate as the patient grows. We present the first case, to the best of our knowledge, of the replacement of a small-diameter stent with a large-diameter stent during Fontan surgery.


Assuntos
Stents Farmacológicos , Técnica de Fontan , Veias Pulmonares , Humanos , Técnica de Fontan/efeitos adversos , Stents , Veias Pulmonares/cirurgia , Artéria Pulmonar/cirurgia , Resultado do Tratamento
9.
Eur Heart J Case Rep ; 7(8): ytad353, 2023 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-37559783

RESUMO

Background: Several side effects have been reported after mRNA COVID-19 vaccinations. Nonetheless, the risk of pulmonary hypertension (PH) is rarely reported. Most cases with acute PH following vaccination were due to macropulmonary embolism secondary to deep vein thrombosis. However, acute PH due to microthrombus formation after COVID-19 vaccination has not been reported before, although a microthrombus has been considered to lead to the dysfunction of multiple organs, particularly in patients infected with COVID-19. Case summary: A 63-year-old woman without any past medical history presented to our hospital with facial and bilateral pedal oedema and progressive dyspnoea on exertion. Her symptoms began the day after her second COVID-19 vaccination and developed gradually, which prompted her to seek consultation in our hospital 6 weeks later. An echocardiogram revealed substantially elevated right heart pressure, and cardiac catheterization revealed high pulmonary artery pressure (mean PAP, 30 mmHg). Contrast-enhanced computed tomography and venous echography revealed no apparent thrombus, and ventilation/perfusion (V/Q) scintigraphy revealed no V/Q mismatch. However, elevated D-dimer indicated the presence of a coagulation-fibrinolysis system in her body; thus, heparin therapy was initiated intravenously on Day 3 for 4 days, followed by direct oral anticoagulants ended on Day 16. Her symptoms substantially improved as her D-dimer level decreased, and a follow-up cardiac catheterization on Day 14 revealed a decline in mean PAP (15 mmHg). Discussion: Our case suggests that the presence of acute PH is likely due to microangiopathy. Further studies are required to reveal the relationship between immune responses and microthrombus formation after COVID-19 vaccination.

11.
Eur J Vasc Endovasc Surg ; 66(5): 722-729, 2023 11.
Artigo em Inglês | MEDLINE | ID: mdl-37516380

RESUMO

OBJECTIVE: Poor below knee (BTK) runoff is a predictor of stent failure after endovascular femoropopliteal artery treatment; however, lack of pathological evaluation has prevented characterisation of stent failure. The study aimed to investigate the impact of poor BTK runoff and the antithrombotic effect of the polymer of fluoropolymer coated paclitaxel eluting stents (FP-PESs) in a healthy swine femoropopliteal artery model. METHODS: FP-PESs and bare metal stents (BMSs) and FP-PES and polymer free paclitaxel coated stents (PF-PCSs) were implanted in the bilateral femoral arteries of healthy swine (n = 6, respectively) following coil embolisation in both tibial arteries to induce poor BTK runoff. Histological assessment and intravascular imaging device evaluation were performed at one month. The Japanese Association for Laboratory Animal Science approved the study protocol (reference number: IVT22-90). RESULTS: Optical coherence tomography showed significantly lower percent area stenosis in FP-PES compared with BMS (37.3%, [interquartile range (IQR), 25.6 - 54.3] % vs. 92.5% [IQR, 75.5 - 96.1] %, respectively, p = .031), and PF-PCS (8.3% [IQR, 4.5 - 27.0] % vs. 31.2% [IQR, 23.3 - 52.2] %, respectively, p = .031). Histopathological evaluation demonstrated that thin fibrin attachment without re-stenosis was the most dominant neointimal tissue characteristic in FP-PES. On the other hand, neointimal tissue characteristics with significant restenosis of BMS and PF-PCS were mainly organising or organised thrombus. CONCLUSION: Organising and or organised thrombus attachment due to poor BTK runoff was the main cause of in stent restenosis of the swine femoral artery. FP-PES demonstrated the least percent area stenosis, suggesting the importance of the antithrombotic effect of polymer.


Assuntos
Stents Farmacológicos , Trombose , Suínos , Animais , Artéria Femoral/diagnóstico por imagem , Artéria Femoral/cirurgia , Polímeros de Fluorcarboneto , Fibrinolíticos , Constrição Patológica , Stents , Polímeros , Paclitaxel , Neointima , Trombose/etiologia , Resultado do Tratamento
13.
J Endovasc Ther ; : 15266028231161215, 2023 Mar 23.
Artigo em Inglês | MEDLINE | ID: mdl-36951275

RESUMO

BACKGROUND: A recent meta-analysis of randomized control trials demonstrated a significantly higher risk of major amputation in patients treated with drug-coated balloons (DCBs) compared with standard treatment, especially in high-dose paclitaxel-coated DCBs. Distal particulate embolization after DCB use was considered a potential cause of the higher incidence of major amputation. The current study aimed to histologically and biologically compare biologic drug effect and distal particulate embolization in 3 DCBs (a high-dose paclitaxel-coated DCB [IN.PACT Admiral] and 2 low-dose paclitaxel-coated DCBs [Ranger and Lutonix]). METHODS AND RESULTS: The DCBs were inflated in the healthy descending aortas of 18 rabbits, followed by euthanasia 28 days after the procedure. The treated descending aorta and distal skeletal muscles were histopathologically evaluated, and paclitaxel concentrations were measured. The paclitaxel concentration of the treated lesion was highest for Ranger, followed by IN.PACT and Lutonix (Ranger vs IN.PACT vs Lutonix: 1089 [745-2170] pmol/mg vs 638 [160-2075] pmol/mg vs 25 [10-304] pmol/mg, respectively; p<0.0001). In the histopathological evaluation, the angle of severe medial smooth muscle cell loss was largest for Ranger followed by IN.PACT and Lutonix (12.8 [8.0-20.4] degree vs 1.4 [1.2-5.2] degree vs 0.8 [0.5-2.5] degree, respectively), with significant differences for Ranger vs IN.PACT (p=0.007) and Ranger vs Lutonix (p=0.002). However, paclitaxel concentrations of distal skeletal muscles were lowest for Lutonix, followed by Ranger and IN.PACT (12 [1-58] pmol/mg vs 15 [13-21] pmol/mg vs 42 [19-108] pmol/mg, respectively, p<0.0001). The numbers of arteries with downstream DCB effects were highest for IN.PACT, followed by Ranger and Lutonix (Ranger vs IN.PACT vs Lutonix, 3 [3-4] vs 4 [3-7] vs 2 [1-2], respectively), which was consistent with the measured tissue paclitaxel concentrations. CONCLUSION: These findings suggest that Ranger demonstrates the strongest paclitaxel effect, as well as the second-best effect regarding distal particulate embolization, making it a good treatment option for patients with peripheral artery disease among the 3 DCBs evaluated in the current study. Further clinical head-to-head comparisons with larger numbers of patients are needed to explore which DCB is the most effective and safe treatment option.Clinical Impact:The findings of the current preclinical study suggests that Ranger demonstrates the strongest paclitaxel effect, as well as the second-best effect regarding distal particulate embolization making it a good treatment for patients with intermittent claudication and chronic limb-threatening ischemia.

15.
JCI Insight ; 8(5)2023 03 08.
Artigo em Inglês | MEDLINE | ID: mdl-36719758

RESUMO

Vascular calcification (VC) is concomitant with atherosclerosis, yet it remains uncertain why rupture-prone high-risk plaques do not typically show extensive calcification. Intraplaque hemorrhage (IPH) deposits erythrocyte-derived cholesterol, enlarging the necrotic core and promoting high-risk plaque development. Pro-atherogenic CD163+ alternative macrophages engulf hemoglobin:haptoglobin (HH) complexes at IPH sites. However, their role in VC has never been examined to our knowledge. Here we show, in human arteries, the distribution of CD163+ macrophages correlated inversely with VC. In vitro experiments using vascular smooth muscle cells (VSMCs) cultured with HH-exposed human macrophage - M(Hb) - supernatant reduced calcification, while arteries from ApoE-/- CD163-/- mice showed greater VC. M(Hb) supernatant-exposed VSMCs showed activated NF-κB, while blocking NF-κB attenuated the anticalcific effect of M(Hb) on VSMCs. CD163+ macrophages altered VC through NF-κB-induced transcription of hyaluronan synthase (HAS), an enzyme that catalyzes the formation of the extracellular matrix glycosaminoglycan, hyaluronan, within VSMCs. M(Hb) supernatants enhanced HAS production in VSMCs, while knocking down HAS attenuated its anticalcific effect. NF-κB blockade in ApoE-/- mice reduced hyaluronan and increased VC. In human arteries, hyaluronan and HAS were increased in areas of CD163+ macrophage presence. Our findings highlight an important mechanism by which CD163+ macrophages inhibit VC through NF-κB-induced HAS augmentation and thus promote the high-risk plaque development.


Assuntos
Aterosclerose , Placa Aterosclerótica , Calcificação Vascular , Camundongos , Humanos , Animais , NF-kappa B , Ácido Hialurônico , Camundongos Knockout para ApoE , Macrófagos , Aterosclerose/complicações , Apolipoproteínas E/genética
16.
Cardiovasc Interv Ther ; 38(2): 223-230, 2023 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-36609899

RESUMO

BACKGROUND: Excimer laser is used to treat coronary artery disease, especially in case of lesions with thrombus and in-stent restenosis (ISR). However, there are no in vivo preclinical studies that have evaluated the pathological reactions of the vessel wall after excimer laser ablation. METHODS: Bare-metal stents were placed in the external iliac arteries of six healthy rabbits. Twenty-eight days later, excimer laser ablation was performed with low-power (45 (fluency)/25 (rate)) in one side, and high-power (60/40) in the opposite side, followed by optical coherence tomography (OCT) evaluation. Rabbits were sacrificed 15 min after the procedure, and histological assessment was performed. RESULTS: Morphometry analysis of OCT showed similar stent and lumen size between low-power and high-power group. Histological evaluation suggested endothelial cell loss, fibrin deposition, and tissue loss. The low-power group showed significantly less pathological changes compared with the high-power group: angle of endothelial cell loss, 32.4° vs. 191.7° (interquartile range, 8.8°-131.7° vs. 125.7°-279.5°; p < 0.01); fibrin deposition, 1.1° vs. 59.6° (0.0°-70.4° vs. 31.4°-178.4°; p = 0.03); and tissue loss 0.0° vs. 18.2° (0.0°-8.7° vs. 0.0°-42.7°; p = 0.03). CONCLUSIONS: The pathological changes in neointima were more prominent after high-power excimer laser ablation than after low-power excimer laser. To improve safety in clinical practice, understanding the pathological changes of tissues after excimer laser in lesions with ISR is essential.


Assuntos
Angioplastia a Laser , Reestenose Coronária , Animais , Humanos , Coelhos , Neointima/patologia , Lasers de Excimer/uso terapêutico , Artéria Ilíaca/cirurgia , Angiografia Coronária , Stents/efeitos adversos , Fibrina , Tomografia de Coerência Óptica/métodos , Reestenose Coronária/terapia , Resultado do Tratamento
18.
Sci Rep ; 12(1): 13606, 2022 08 10.
Artigo em Inglês | MEDLINE | ID: mdl-35948607

RESUMO

Previous studies have reported that a high neutrophil-to-lymphocyte ratio (NLR) is associated with disease severity and poor prognosis in COVID-19 patients. We aimed to investigate the clinical implications of NLR in patients with COVID-19 complicated with cardiovascular diseases and/or its risk factors (CVDRF). In total, 601 patients with known NLR values were selected from the CLAVIS-COVID registry for analysis. Patients were categorized into quartiles (Q1, Q2, Q3, and Q4) according to baseline NLR values, and demographic and clinical parameters were compared between the groups. Survival analysis was conducted using the Kaplan-Meier method. The diagnostic performance of the baseline and follow-up NLR values was tested using receiver operating characteristic (ROC) curve analysis. Finally, two-dimensional mapping of patient characteristics was conducted using t-stochastic neighborhood embedding (t-SNE). In-hospital mortality significantly increased with an increase in the baseline NLR quartile (Q1 6.3%, Q2 11.0%, Q3 20.5%; and Q4, 26.6%; p < 0.001). The cumulative mortality increased as the quartile of the baseline NLR increased. The paired log-rank test revealed significant differences in survival for Q1 vs. Q3 (p = 0.017), Q1 vs. Q4 (p < 0.001), Q2 vs. Q3 (p = 0.034), and Q2 vs. Q4 (p < 0.001). However, baseline NLR was not identified as an independent prognostic factor using a multivariate Cox proportional hazards regression model. The area under the curve for predicting in-hospital death based on baseline NLR was only 0.682, whereas that of follow-up NLR was 0.893. The two-dimensional patient map with t-SNE showed a cluster characterized by high mortality with high NLR at follow-up, but these did not necessarily overlap with the population with high NLR at baseline. NLR may have prognostic implications in hospitalized COVID-19 patients with CVDRF, but its significance depends on the timing of data collection.


Assuntos
COVID-19 , Doenças Cardiovasculares , COVID-19/complicações , Mortalidade Hospitalar , Humanos , Linfócitos , Neutrófilos , Prognóstico , Curva ROC , Estudos Retrospectivos , Fatores de Risco
19.
Circ Rep ; 4(7): 315-321, 2022 Jul 08.
Artigo em Inglês | MEDLINE | ID: mdl-35860350

RESUMO

Background: Male sex is associated with a worse clinical course and outcomes of COVID-19, particularly in older patients. However, studies on COVID-19 patients with cardiovascular disease and/or risk factors (CVDRF), which are representative risk factors of COVID-19, are limited. In this study, we investigated the effect of sex on the outcomes of hospitalized COVID-19 patients with CVDRF. Methods and Results: We analyzed 693 COVID-19 patients with CVDRF. Patients were divided into 2 groups based on sex, and baseline characteristics and in-hospital outcomes were compared between the 2 groups. The mean age of the 693 patients was 68 years; 64.8% were men and 96.1% were Japanese. In a univariate analysis model, sex was not significantly associated with in-hospital mortality (odds ratio [OR] 1.22; 95% confidence interval [CI] 0.74-2.02; P=0.43). However, men had higher in-hospital mortality than women, especially among older (age ≥80 years) patients (OR 2.21; 95% CI 1.11-4.41; P=0.024). After adjusting for age and pivotal risk factors (hypertension, diabetes, heart failure, coronary artery disease, chronic lung disease, and chronic kidney disease), multivariate analysis suggested that male sex was an independent predictor of in-hospital mortality (OR 2.20; 95% CI 1.23-3.92; P=0.008). Conclusions: In this post hoc analysis of a nationwide registry focusing on patients with COVID-19 and CVDRF, men had higher in-hospital mortality than women, especially among older patients.

20.
Cardiovasc Interv Ther ; 37(4): 597-612, 2022 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-35852760

RESUMO

Imaging modalities have developed to provide precise information in the assessment of lower extremity artery disease (LEAD), including both quantitative measurements and morphological assessment. However, a lack of standardization for the evaluation methods introduces inconsistency and potential risk. This consensus document from Japan Endovascular Treatment Conference (JET) summarizes the methods of measurement and assessment of intravascular ultrasound (IVUS), optical frequency domain imaging (OFDI), and angioscopy. We propose standardized approaches for the evaluation of these modalities in endovascular therapy (EVT).


Assuntos
Vasos Coronários , Ultrassonografia de Intervenção , Consenso , Vasos Coronários/diagnóstico por imagem , Humanos , Japão , Extremidade Inferior/diagnóstico por imagem , Padrões de Referência , Tomografia de Coerência Óptica/métodos , Ultrassonografia de Intervenção/métodos